BOILER WATER TREATMENT

CUSTOMIZED BOILER WATER TREATMENT

Boiler system components, and the mechanisms by which deposits form and corrosion occurs, are varied and complex. Boiler systems require effective chemical treatment and accurate monitoring and control.

AquaTech field engineers provide the highest level of boiler expertise available, and our specialists can offer guidance and recommendations for treating a wide range of systems, from high-pressure steam generators to hot water boilers. We offer a full line of boiler water treatment chemicals, testing, and control equipment at an economical cost. Our boiler treatment programs can increase system efficiency, decrease plant downtime and maintenance costs, and extend equipment life.
A steam generator water treatment program is primarily designed to keep heat transfer surfaces (boilers, condensate/feedwater systems, and, where applicable, steam turbines) free from deposition and corrosion. Boiler deposits typically contain undesirable levels of metal oxides, mineral scale, or sludge that can affect circulation and heat transfer, and initiate underdeposit corrosion. Corrosion in lower-pressure boilers is frequently the result of air ingress and dissolved oxygen concentration during unit downtimes. These phenomena often lead to failures and unscheduled shutdowns, but our boiler treatment chemicals and solutions can help improve your boiler system efficiency while reducing maintenance costs.

Steam Generator System Evaluations

Protection of all networks within a steam generating plant (pre-boiler, boiler, and post-boiler) is critical for efficient, safe, and reliable operation. Apart from the required inspections from your plant’s insurance firm, regular consultations and system walk-downs by water treatment personnel can be a key aspect in evaluating the integrity of such system components.
AquaTech field engineers have more experience with boiler water treatment than any other technical team in the industry. After evaluating the steam generator network, our technical experts can identify items to improve plant efficiency and equipment reliability. Below is a list of just some of the equipment or locations where process evaluations can be very beneficial:
Our field engineers can assist in the examination of both the steam and water-side of condensers, as well as auxiliary and heat exchanger examinations.

Boiler Water Treatment Chemicals & Service

AquaTech has the most experienced technical personnel among boiler water treatment companies. We can provide the expertise and chemistry to protect the entire steam generator network.

Makeup Water Treatment

Depending on the steam generator pressure, makeup treatment may range from simple softening to sophisticated demineralization. Ingress of impurities into a steam generator can cause significant and sometimes catastrophic problems if not detected and corrected promptly. AquaTech personnel can assist in evaluating the required system for the application, and can also help troubleshoot when a system malfunctions.

Condensate / Feedwater

Proper condensate/feedwater treatment is of utmost importance in boiler operations. In-leakage of impurities via a condenser tube failure can cause ruinous damage in steam generator tubes. AquaTech has application experience and solutions for detecting impurity ingress and protecting your boiler feedwater system from corrosion.

AquaTech personnel can help you determine whether a deaerator is needed in your system, and help solve deaerator issues, including:

  • Misaligned or damaged deaerator trays
  • Improper or damaged pressure-reducing valves
  • Failure to maintain continuous positive steam pressure
  • Infrequent or improper venting
  • Leaks in the external vent condenser

Boiler Water Treatment

Even when feedwater chemistry is controlled within ASME or IAPWS guidelines, internal boiler treatment is still necessary to control deposition and corrosion in the high-temperature environment of the steam generator. Preventing excess carryover of impurities to the steam system is also critical. Like treatment for condensate/feedwater, boiler chemistry programs continue to evolve. AquaTech personnel can advise on chemistry and provide boiler treatment chemicals to keep systems in proper order.

Depending on the steam generator configuration and pressure, one of several internal treatments may be best. Boiler water chemistry evaluation and monitoring is also highly important to ensure impurities do not carry over to the steam system.

Steam and Condensate

Depending on the steam generator configuration and pressure, one of several internal treatments may be best. Boiler water chemistry evaluation and monitoring is also highly important to ensure impurities do not carry over to the steam system.

Steam and Condensate

Carryover of excess impurities from the boiler can cause significant downstream problems. In units equipped with steam turbines, contaminant ingress may potentially lead to catastrophic conditions such as turbine blade cracking and subsequent failure.

Even with proper chemistry control, a variety of mechanical factors may influence boiler and steam system conditions, including:

  • Fluctuations in the boiler water level, which can either expose tubes to overheating or overwhelm steam separators and introduce contaminants.
  • Failure of a water/steam separator in the drum that allows excess moisture to enter the steam system.
  • Introduction of impurities directly to the steam via the attemperator system.
In low-pressure boilers, mechanical carryover (the entrainment of water in the steam) can be caused by a high concentration of dissolved solids in the boiler water, resulting in surface tension reduction and boiler water destabilization, and potential foaming in the steam drum. Transported impurities may deposit on superheater tubes, causing tube failures. AquaTech experts can assist plant personnel in evaluating these conditions, and subsequently provide defoaming chemicals and technical procedures to address carryover issues. Our field engineers can perform tests to determine boiler steam purity, evaluate the system operation, and customize a solution to eliminate carryover.
In many industrial plants, steam passes through numerous heat exchangers, with a varying amount of the exhaust steam recovered as condensate. This condensate may accumulate numerous impurities in the process. A very common impurity is carbon dioxide, which converts to carbonic acid in the condensate, lowers the condensate pH, and corrodes metals. If left untreated, acidic condensate will corrode lengths of condensate return piping, pipe threads, nipples, and elbows, resulting in leaks and process equipment deterioration and failure. AquaTech personnel can provide expertise on proper corrosion inhibitors and neutralizing/filming chemicals to protect condensate return systems.
Many other impurities may infiltrate condensate return.  Some of these include:
  • Suspended solids, including metal oxides
  • Organic compounds, sometimes including oil and grease
  • Dissolved mineral salts
These impurities can cause significant problems in steam generators, including corrosion, deposition, and foaming. AquaTech personnel can advise on treatment methods and equipment to mitigate these issues with custom boiler water treatment programs and chemicals designed to meet your unique system needs.

Steam Generator Layup

Boilers often need to be taken out of service for a variety of reasons, including seasonal shutdowns, temporary lapses in production, maintenance, or annual inspections by the insurance provider. Plant personnel often forget major corrosion will occur in steam generators without proper layup procedures. Not only does corrosion damage piping and other equipment, but the corrosion products also transport to the steam generator during startups and deposit on tube surfaces. This can lead to severe underdeposit corrosion. AquaTech has expertise in both wet (short-term and extended) and dry layups. Our boiler treatment programs utilize filming amines, and/or moisture-absorbing chemicals and vapor-phase corrosion inhibitors. Contact AquaTech field engineer to learn how best to lay up your boiler system.

Water/Steam Chemistry Monitoring

Chemistry upsets have been known to cause boiler tube failures within days, sometimes even hours. Thus, continuous, on-line monitoring is vital for protecting steam generators. AquaTech personnel can provide expert advice on the equipment and sampling points necessary to protect your steam generator from chemistry upsets. Modern analytical equipment can also be configured to operate chemical feed systems to provide precise control of unit chemistry.

TRUST OUR EXPERT BOILER WATER TREATMENT COMPANY

AquaTech is a trusted boiler water treatment company with over 15 years of service and expertise. Our experienced field team and laboratory services allow us to provide custom boiler treatment chemicals and water treatment solutions for boilers. We’re here to help you improve the efficiency of your facility and decrease operational costs. Contact us online to get in touch with our experts and schedule a consultation.